Filter By Pipettor Attributes

Model: 8

Type/Channels: 5

Max Volume:




Help

Manufacturers

[ALL]
EPPENDORF
HAMAMATSU
HAMILTON COMPANY
LABNET INTERNATIONAL
MOLECULAR DEVICES
NICHIRYO/OXFORD
VISTALAB TECHNOLOGIES
WHEATON/SOCOREX

 
 

Pipettors

Find the best deals on pipettors at the Lab Procurement Services store!

Records Found: 18

Sort by:     Part Number   Description   Reset Sorting

Page: First Previous 1 2 3 Next Last 

Description: Wheaton Socorex Acura 815 Fixed 700µL
Part Number: W810046

Lightweight pipettors are designed for precise, accurate pipetting of solutions, reagents, acids, serums, and other liquids, and for gel-sequencing applications. Dispensing is accomplished with a single plunger stroke. A differentiated overshoot function and separate push button for tip ejection reduce dead volume and prevent accidental de-tipping. The glove-friendly JustTip™ adjustable tip ejector allows the use of most pipet tips. The stainless steel and PVDF plunger assembly is chemically resistant. Autoclavable to 121°C (250°F) without disassembly or recalibration. Ordering Information: Supplied with a manufacturer’s three-year warranty, including a two-year warranty on the original calibration. The 2000µL pipettor includes an adapter for use with a Pasteur pipet. Pipettors 83009-148, -150, -152, and -154 are supplied with cellulose paper filters that may be used with polypropylene tips to prevent cross-contamination.

  • Manufacturer: Wheaton
    Model: Acura 815

  • Volume Range (µL): 700 - 700
    Channels: 1

Description: Vistalab MLA D-Tipper Fixed Volume 700 µL
Part Number: 1162C

MLA pipettefixed volume 700uL. Features single plunger action and auto detipping.Tapered design for narrow tubes. For use where dependable delivery and highly accurate volumes are required. Color coded-silver. Manufactured for durability and reliability.

  • Manufacturer: Vistalab
    Model: MLA DT-Fixed Volume

  • Volume Range (µL): 700 - 700
    Channels: 1

Description: Labnet Clinipet Fixed Volume 700µL
Part Number: P3900-700

An ergonomically designed body and finger rest make these pipettes comfortable to hold, even during extended pipetting sessions. The smooth plunger action and unique twist-eject tip removal system require minimal force and aid in reducing the risk of repetitive strain injuries. Manufactured from lightweight, high impact plastic, the Labpette™ FX pipettes are extremely durable, offer excellent chemical resistance and retain their high level of accuracy and precision during repeated use. Both the shaft and tip ejector are autoclavable. Labpette™ FX pipettes are color coded for easy identification and proper tip selection. Each pipette is individually tested, supplied with a factory calibration certificate and covered by a lifetime warranty.

  • Manufacturer: Labnet
    Model: Clinipet Fixed Volume

  • Volume Range (µL): 700 - 700
    Channels: 1

Description: Hamilton 1750 TLL Syringe with Slots, 500 µL, Luer Lock Syringe w/o Needle, 48.3 bar (700 psig) Max Pressure, Each
Part Number: 81227

These syringes are the Gastight® version of the original 700 series syringes and are ideal for dispensing volumes from 1μL up to 500μL. Gastight® syringes are ideal for dispensing both liquids and gases and have a precision-machined PTFE plunger tip which creates a leak-free seal. With the tight fit, the tip essentially wipes the interior of the syringe barrel free of sample. This feature is particularly useful with heterogeneous samples as it reduces the chance that a deposit will occur and cause the plunger to freeze. Fluid path includes SST, borosilicate glass, and PTFE. Syringes are gas sterilizable. A variety of different terminations and needle point styles are available. Terminations include cemented needle, removable needle, luer tip, and PTFE luer lock. Syringe Terminations: Cemented needles for low volume syringes are cemented into the glass syringe barrel at a point corresponding to the zero graduation mark. With this termination, dead volume is limited to the internal volume of the needle. Not autoclavable. Needle gauge is determined by the syringe volume and are not user-selectable. Removable needles are a Hamilton-specific design. The design allows the needles to seat precisely at the zero graduation mark of the syringe. Users can select the needle gauge, length, and point style to optimize the syringe for custom applications. This termination allows for a removable needle without increasing the dead volume of the syringe and is ideal when there is a risk of the needle clogging. Autoclavable when disassembled. Repeated autoclaving will shorten syringe life. Luer tip needles are removable and fit over a ground glass hub which is tapered in the shape of a male luer. This termination will accept most hypodermic needles but was designed specifically for use with Hamilton Kel-F needles. This termination also increases the dead volume in the syringe, which may not be appropriate for some applications. Autoclavable to 115°C when disassembled. PTFE luer lock termination has a PTFE, male Luer taper with nickelplated brass locking hub for use with Kel-F needles, metal hub needles, and universal connectors. It is also used with Hamilton diluters/dispensers, OEM applications, and manual operations. The version with slots is used during the attachment to some instruments but does not effect the connection to needles. Not autoclavable (25mL and greater syringes). Needle Point Styles: Point style 2 is a sharp, beveled, curved, non-coring needle point recommended for septum penetration. Point style 3 is a blunt needle point for use with HPLC injection valves and for sample pipetting. Point style 5 is a conical needle with side port for penetration of septa, thin-gauged vinyls and plastics without coring.

  • Manufacturer: Hamilton
    Model: 1700

  • Volume Range (µL): 0 - 500
    Channels: SYRINGE

Description: Hamilton 1750 TLL Syringe, 500 µL, Luer Lock Syringe w/o Needle, 48.3 bar (700 psig) Max Pressure, Each
Part Number: 81220

These syringes are the Gastight® version of the original 700 series syringes and are ideal for dispensing volumes from 1μL up to 500μL. Gastight® syringes are ideal for dispensing both liquids and gases and have a precision-machined PTFE plunger tip which creates a leak-free seal. With the tight fit, the tip essentially wipes the interior of the syringe barrel free of sample. This feature is particularly useful with heterogeneous samples as it reduces the chance that a deposit will occur and cause the plunger to freeze. Fluid path includes SST, borosilicate glass, and PTFE. Syringes are gas sterilizable. A variety of different terminations and needle point styles are available. Terminations include cemented needle, removable needle, luer tip, and PTFE luer lock. Syringe Terminations: Cemented needles for low volume syringes are cemented into the glass syringe barrel at a point corresponding to the zero graduation mark. With this termination, dead volume is limited to the internal volume of the needle. Not autoclavable. Needle gauge is determined by the syringe volume and are not user-selectable. Removable needles are a Hamilton-specific design. The design allows the needles to seat precisely at the zero graduation mark of the syringe. Users can select the needle gauge, length, and point style to optimize the syringe for custom applications. This termination allows for a removable needle without increasing the dead volume of the syringe and is ideal when there is a risk of the needle clogging. Autoclavable when disassembled. Repeated autoclaving will shorten syringe life. Luer tip needles are removable and fit over a ground glass hub which is tapered in the shape of a male luer. This termination will accept most hypodermic needles but was designed specifically for use with Hamilton Kel-F needles. This termination also increases the dead volume in the syringe, which may not be appropriate for some applications. Autoclavable to 115°C when disassembled. PTFE luer lock termination has a PTFE, male Luer taper with nickelplated brass locking hub for use with Kel-F needles, metal hub needles, and universal connectors. It is also used with Hamilton diluters/dispensers, OEM applications, and manual operations. The version with slots is used during the attachment to some instruments but does not effect the connection to needles. Not autoclavable (25mL and greater syringes). Needle Point Styles: Point style 2 is a sharp, beveled, curved, non-coring needle point recommended for septum penetration. Point style 3 is a blunt needle point for use with HPLC injection valves and for sample pipetting. Point style 5 is a conical needle with side port for penetration of septa, thin-gauged vinyls and plastics without coring.

  • Manufacturer: Hamilton
    Model: 1700

  • Volume Range (µL): 0 - 500
    Channels: SYRINGE

Description: Hamamatsu FDSS7000
Part Number: HAMAMATSU 7000

A high throughput screening (HTS) plate reader that dispenses and images 96, 384, or 1536 well plates, with many added features such as stackers or robotics-compatibility for fully-automated operation.

  • Manufacturer: Hamamatsu
    Model: Model 7000

  • Volume Range (µL): 0 - 50000
    Channels: 1

Description: Nichiryo Nichipet 7000 12-Channel 0.5 - 10µL
Part Number: 00-NP7-12V

Multi-Channel Pipette 12-channel pipette. Completely autoclavable at 121°C for 20 minutes. UV resistant. Improved ergonomic design allows fatigue-free operations. Easy and convenient single hand locking lever. Head revolves 360° to allow for comfortable d

  • Manufacturer: Nichiryo
    Model: Nichipet 7000

  • Volume Range (µL): 0.5 - 10
    Channels: 12