Model: 183

Type/Channels: 9

Max Volume:




Help

Manufacturers

[ALL]
A. DAIGER
AXYGEN SCIENTIFIC
BECKMAN COULTER
BEL-ART
BIOHIT
BIOTIX
BRANDTECH SCIENTIFIC
CAPP
CLAY ADAMS
COLE PARMER
CORNING
DENVILLE SCIENTIFIC
DRUMMOND
EPPENDORF
EXCALIBUR LABS
EXTRAGENE
GILSON
GLOBE SCIENTIFIC
HACH
HAMILTON COMPANY
HELENA LABS
JENCONS
LABNET INTERNATIONAL
LAKE CHARLES
METTLER (ANACHEM)
NATIONAL SCIENTIFIC SUPPLY
NICHIRYO/OXFORD
PHENIX
QORPAK
RAININ
RICE LAKE
RITTER
SILOGEX
STOCKWELL SCIENTIFIC
THERMO FINNPIPETTE
THERMO FISHER
TITERTEK
ULSTER SCIENTIFIC INC.
USA SCIENTIFIC PLASTICS
VISTALAB TECHNOLOGIES
VOLAC
VWR INTERNATIONAL
WHEATON/SOCOREX
WILKEM SCIENTIFIC
WORLD PRECISION INSTRUMENTS

 
 

Pipettors

Find the best deals on pipettors at the Lab Procurement Services store!

Records Found: 324

Sort by:     Part Number   Description   Reset Sorting

Page: First Previous ... 6 7 8 9 10  ... Next Last 

Description: Hamilton 1710 TLL Syringe, 100 µL, Luer Lock Syringe w/o Needle, 68.9 bar (1000 psig) Max Pressure, Each
Part Number: 81020

These syringes are the Gastight® version of the original 700 series syringes and are ideal for dispensing volumes from 1μL up to 500μL. Gastight® syringes are ideal for dispensing both liquids and gases and have a precision-machined PTFE plunger tip which creates a leak-free seal. With the tight fit, the tip essentially wipes the interior of the syringe barrel free of sample. This feature is particularly useful with heterogeneous samples as it reduces the chance that a deposit will occur and cause the plunger to freeze. Fluid path includes SST, borosilicate glass, and PTFE. Syringes are gas sterilizable. A variety of different terminations and needle point styles are available. Terminations include cemented needle, removable needle, luer tip, and PTFE luer lock. Syringe Terminations: Cemented needles for low volume syringes are cemented into the glass syringe barrel at a point corresponding to the zero graduation mark. With this termination, dead volume is limited to the internal volume of the needle. Not autoclavable. Needle gauge is determined by the syringe volume and are not user-selectable. Removable needles are a Hamilton-specific design. The design allows the needles to seat precisely at the zero graduation mark of the syringe. Users can select the needle gauge, length, and point style to optimize the syringe for custom applications. This termination allows for a removable needle without increasing the dead volume of the syringe and is ideal when there is a risk of the needle clogging. Autoclavable when disassembled. Repeated autoclaving will shorten syringe life. Luer tip needles are removable and fit over a ground glass hub which is tapered in the shape of a male luer. This termination will accept most hypodermic needles but was designed specifically for use with Hamilton Kel-F needles. This termination also increases the dead volume in the syringe, which may not be appropriate for some applications. Autoclavable to 115°C when disassembled. PTFE luer lock termination has a PTFE, male Luer taper with nickelplated brass locking hub for use with Kel-F needles, metal hub needles, and universal connectors. It is also used with Hamilton diluters/dispensers, OEM applications, and manual operations. The version with slots is used during the attachment to some instruments but does not effect the connection to needles. Not autoclavable (25mL and greater syringes). Needle Point Styles: Point style 2 is a sharp, beveled, curved, non-coring needle point recommended for septum penetration. Point style 3 is a blunt needle point for use with HPLC injection valves and for sample pipetting. Point style 5 is a conical needle with side port for penetration of septa, thin-gauged vinyls and plastics without coring.

  • Manufacturer: Hamilton
    Model: 1700

  • Volume Range (µL): 0 - 100
    Channels: SYRINGE

Description: Hamilton 1705 TLL Syringe with Slots, 50 µL, Luer Lock Syringe w/o Needle, 68.9 bar (1000 psig) Max Pressure, Each
Part Number: 80927

These syringes are the Gastight® version of the original 700 series syringes and are ideal for dispensing volumes from 1μL up to 500μL. Gastight® syringes are ideal for dispensing both liquids and gases and have a precision-machined PTFE plunger tip which creates a leak-free seal. With the tight fit, the tip essentially wipes the interior of the syringe barrel free of sample. This feature is particularly useful with heterogeneous samples as it reduces the chance that a deposit will occur and cause the plunger to freeze. Fluid path includes SST, borosilicate glass, and PTFE. Syringes are gas sterilizable. A variety of different terminations and needle point styles are available. Terminations include cemented needle, removable needle, luer tip, and PTFE luer lock. Syringe Terminations: Cemented needles for low volume syringes are cemented into the glass syringe barrel at a point corresponding to the zero graduation mark. With this termination, dead volume is limited to the internal volume of the needle. Not autoclavable. Needle gauge is determined by the syringe volume and are not user-selectable. Removable needles are a Hamilton-specific design. The design allows the needles to seat precisely at the zero graduation mark of the syringe. Users can select the needle gauge, length, and point style to optimize the syringe for custom applications. This termination allows for a removable needle without increasing the dead volume of the syringe and is ideal when there is a risk of the needle clogging. Autoclavable when disassembled. Repeated autoclaving will shorten syringe life. Luer tip needles are removable and fit over a ground glass hub which is tapered in the shape of a male luer. This termination will accept most hypodermic needles but was designed specifically for use with Hamilton Kel-F needles. This termination also increases the dead volume in the syringe, which may not be appropriate for some applications. Autoclavable to 115°C when disassembled. PTFE luer lock termination has a PTFE, male Luer taper with nickelplated brass locking hub for use with Kel-F needles, metal hub needles, and universal connectors. It is also used with Hamilton diluters/dispensers, OEM applications, and manual operations. The version with slots is used during the attachment to some instruments but does not effect the connection to needles. Not autoclavable (25mL and greater syringes). Needle Point Styles: Point style 2 is a sharp, beveled, curved, non-coring needle point recommended for septum penetration. Point style 3 is a blunt needle point for use with HPLC injection valves and for sample pipetting. Point style 5 is a conical needle with side port for penetration of septa, thin-gauged vinyls and plastics without coring.

  • Manufacturer: Hamilton
    Model: 1700

  • Volume Range (µL): 0 - 50
    Channels: SYRINGE

Description: Hamilton 1705 TLL Syringe, 50 µL, Luer Lock Syringe w/o Needle, 68.9 bar (1000 psig) Max Pressure, Each
Part Number: 80920

These syringes are the Gastight® version of the original 700 series syringes and are ideal for dispensing volumes from 1μL up to 500μL. Gastight® syringes are ideal for dispensing both liquids and gases and have a precision-machined PTFE plunger tip which creates a leak-free seal. With the tight fit, the tip essentially wipes the interior of the syringe barrel free of sample. This feature is particularly useful with heterogeneous samples as it reduces the chance that a deposit will occur and cause the plunger to freeze. Fluid path includes SST, borosilicate glass, and PTFE. Syringes are gas sterilizable. A variety of different terminations and needle point styles are available. Terminations include cemented needle, removable needle, luer tip, and PTFE luer lock. Syringe Terminations: Cemented needles for low volume syringes are cemented into the glass syringe barrel at a point corresponding to the zero graduation mark. With this termination, dead volume is limited to the internal volume of the needle. Not autoclavable. Needle gauge is determined by the syringe volume and are not user-selectable. Removable needles are a Hamilton-specific design. The design allows the needles to seat precisely at the zero graduation mark of the syringe. Users can select the needle gauge, length, and point style to optimize the syringe for custom applications. This termination allows for a removable needle without increasing the dead volume of the syringe and is ideal when there is a risk of the needle clogging. Autoclavable when disassembled. Repeated autoclaving will shorten syringe life. Luer tip needles are removable and fit over a ground glass hub which is tapered in the shape of a male luer. This termination will accept most hypodermic needles but was designed specifically for use with Hamilton Kel-F needles. This termination also increases the dead volume in the syringe, which may not be appropriate for some applications. Autoclavable to 115°C when disassembled. PTFE luer lock termination has a PTFE, male Luer taper with nickelplated brass locking hub for use with Kel-F needles, metal hub needles, and universal connectors. It is also used with Hamilton diluters/dispensers, OEM applications, and manual operations. The version with slots is used during the attachment to some instruments but does not effect the connection to needles. Not autoclavable (25mL and greater syringes). Needle Point Styles: Point style 2 is a sharp, beveled, curved, non-coring needle point recommended for septum penetration. Point style 3 is a blunt needle point for use with HPLC injection valves and for sample pipetting. Point style 5 is a conical needle with side port for penetration of septa, thin-gauged vinyls and plastics without coring.

  • Manufacturer: Hamilton
    Model: 1700

  • Volume Range (µL): 0 - 50
    Channels: SYRINGE

Description: Hamilton 1710 TLL Syringe with Slots, 100 µL, Luer Lock Syringe w/o Needle, 68.9 bar (1000 psig) Max Pressure, Each
Part Number: 81027

These syringes are the Gastight® version of the original 700 series syringes and are ideal for dispensing volumes from 1μL up to 500μL. Gastight® syringes are ideal for dispensing both liquids and gases and have a precision-machined PTFE plunger tip which creates a leak-free seal. With the tight fit, the tip essentially wipes the interior of the syringe barrel free of sample. This feature is particularly useful with heterogeneous samples as it reduces the chance that a deposit will occur and cause the plunger to freeze. Fluid path includes SST, borosilicate glass, and PTFE. Syringes are gas sterilizable. A variety of different terminations and needle point styles are available. Terminations include cemented needle, removable needle, luer tip, and PTFE luer lock. Syringe Terminations: Cemented needles for low volume syringes are cemented into the glass syringe barrel at a point corresponding to the zero graduation mark. With this termination, dead volume is limited to the internal volume of the needle. Not autoclavable. Needle gauge is determined by the syringe volume and are not user-selectable. Removable needles are a Hamilton-specific design. The design allows the needles to seat precisely at the zero graduation mark of the syringe. Users can select the needle gauge, length, and point style to optimize the syringe for custom applications. This termination allows for a removable needle without increasing the dead volume of the syringe and is ideal when there is a risk of the needle clogging. Autoclavable when disassembled. Repeated autoclaving will shorten syringe life. Luer tip needles are removable and fit over a ground glass hub which is tapered in the shape of a male luer. This termination will accept most hypodermic needles but was designed specifically for use with Hamilton Kel-F needles. This termination also increases the dead volume in the syringe, which may not be appropriate for some applications. Autoclavable to 115°C when disassembled. PTFE luer lock termination has a PTFE, male Luer taper with nickelplated brass locking hub for use with Kel-F needles, metal hub needles, and universal connectors. It is also used with Hamilton diluters/dispensers, OEM applications, and manual operations. The version with slots is used during the attachment to some instruments but does not effect the connection to needles. Not autoclavable (25mL and greater syringes). Needle Point Styles: Point style 2 is a sharp, beveled, curved, non-coring needle point recommended for septum penetration. Point style 3 is a blunt needle point for use with HPLC injection valves and for sample pipetting. Point style 5 is a conical needle with side port for penetration of septa, thin-gauged vinyls and plastics without coring.

  • Manufacturer: Hamilton
    Model: 1700

  • Volume Range (µL): 0 - 100
    Channels: SYRINGE

Description: Fisher Science Education Variable 100 - 1000µL
Part Number: TF-ED1-1000

  • Manufacturer: Thermo Fisher
    Model: Fisher Science Education

  • Volume Range (µL): 100 - 1000
    Channels: 1

Description: Fisher Science Education Variable 1000 - 5000µL
Part Number: TF-ED1-5000

  • Manufacturer: Thermo Fisher
    Model: Fisher Science Education

  • Volume Range (µL): 1000 - 5000
    Channels: 1

Description: Fisherbrand Elite, 100-1000uL
Part Number: FBE01000

The Fisherbrand Elite pipetter has a new, improved ergonomic design providing index finger and hand support for maximum comfort. The low plunger force combined with a larger soft-touch ejection tip helps you work longer without fatigue. Ensuring the success of the application where sterile products are required, the entire pipetter can be steam autoclaved. The Elite pipetter's double action pipetting button's rotating upper disc prevents accidental volume alteration during pipetting. An extremely large display provides better visibility of the selected volume. This comprehensive product line offers a wide volume range for multiple pipetting applications and excels in accuracy and precision. Soft-touch tip ejector, Comfortable, lightweight handle with finger rest, Optimal fit to SureOne pipet tips, Extremely low plunger forces, Fully autoclavable.

  • Manufacturer: Fisher Scientific
    Model: Elite

  • Volume Range (µL): 100 - 1000
    Channels: 1