Filter By Pipettor Attributes

Model: 382

Type/Channels: 14

Max Volume:




Help

Manufacturers

[ALL]
3M
A AND D ENGINEERING
A. DAIGER
AGILENT TECHNOLOGIES
AURORA BIOMED
AXYGEN SCIENTIFIC
BECKMAN COULTER
BEL-ART
BIOHIT
BIOTEK
BIOTIX
BRANDTECH SCIENTIFIC
CAPP
CLAY ADAMS
COLE PARMER
CORNING
DENVILLE SCIENTIFIC
DRUMMOND
DYNMAIC DEVICES
EPPENDORF
EXCALIBUR LABS
EXTRAGENE
GILSON
GLOBE SCIENTIFIC
HACH
HAMAMATSU
HAMILTON COMPANY
HELENA LABS
JENCONS
LABNET INTERNATIONAL
LAKE CHARLES
METTLER (ANACHEM)
MOLECULAR DEVICES
NATIONAL SCIENTIFIC SUPPLY
NICHIRYO/OXFORD
PERKIN ELMER
PHENIX
PROGROUP (WELLPRO)
PROTODYNE
QIAGEN
QORPAK
RAININ
RICE LAKE
RITTER
SGE
SILOGEX
STOCKWELL SCIENTIFIC
TECAN AG
THERMO FINNPIPETTE
THERMO FISHER
THERMO MATRIX
TITERTEK
ULSTER SCIENTIFIC INC.
USA SCIENTIFIC PLASTICS
VISTALAB TECHNOLOGIES
VOLAC
VWR INTERNATIONAL
WHEATON/SOCOREX
WILKEM SCIENTIFIC
WORLD PRECISION INSTRUMENTS

 
 

Pipettors

Find the best deals on pipettors at the Lab Procurement Services store!
If it's not in our catalog, click "Get a Quote" to request pricing.

Records Found: 2974

Sort by: Price High   Price Low   Part Number   Description   Reset Sorting

Page: First Previous ... 246 247 248 249 250  ... Next Last 

Description: Hamilton 1810 Small, RN Syringe, 22s Gauge, 100 µL, Each
Part Number: 84886

The 1800 series is the reinforced plunger version of the 1700 series syringe. Attached to the flange of the syringe is a removable blue syringe holder that prevents heat transfer, dispense inaccuracies and plunger blow outs. It also provides support to small volume plungers that are prone to bending during injection. Ideal for dispensing both liquids and gases. They have a precision-machined PTFE plunger tip which creates a leak-free seal. With the tight fit, the tip essentially wipes the interior of the syringe barrel free of sample. This feature is particularly useful with heterogeneous samples as it reduces the chance that a deposit will occur and cause the plunger to freeze. Fluid path is SST, borosilicate glass, and PTFE. Gas sterilizable. This series is ideal for dispensing volumes from 1μL up to 500μL. A variety of different terminations and needle options are available. Syringe Terminations: Cemented needles for low volume syringes are cemented into the glass syringe barrel at a point corresponding to the zero graduation mark. With this termination, dead volume is limited to the internal volume of the needle. Not autoclavable. Needle gauge is determined by the syringe volume and are not user-selectable. Removable needles are a Hamilton-specific design. The design allows the needles to seat precisely at the zero graduation mark of the syringe. Users can select the needle gauge, length, and point style to optimize the syringe for custom applications. This termination also allows for a removable needle without increasing the dead volume of the syringe and is ideal when there is a risk of the needle clogging. Autoclavable when disassembled. Repeated autoclaving will shorten syringe life. Needle Point Style: Point style 2 is a sharp, beveled, curved, non-coring needle point recommended for septum penetration.

  • Manufacturer: Hamilton
    Model: 1800

  • Volume Range (µL): 0 - 100
    Channels: SYRINGE

Description: Hamilton 1802 Small, RN Syringe, 22s Gauge, 25 µL, Each
Part Number: 84880

The 1800 series is the reinforced plunger version of the 1700 series syringe. Attached to the flange of the syringe is a removable blue syringe holder that prevents heat transfer, dispense inaccuracies and plunger blow outs. It also provides support to small volume plungers that are prone to bending during injection. Ideal for dispensing both liquids and gases. They have a precision-machined PTFE plunger tip which creates a leak-free seal. With the tight fit, the tip essentially wipes the interior of the syringe barrel free of sample. This feature is particularly useful with heterogeneous samples as it reduces the chance that a deposit will occur and cause the plunger to freeze. Fluid path is SST, borosilicate glass, and PTFE. Gas sterilizable. This series is ideal for dispensing volumes from 1μL up to 500μL. A variety of different terminations and needle options are available. Syringe Terminations: Cemented needles for low volume syringes are cemented into the glass syringe barrel at a point corresponding to the zero graduation mark. With this termination, dead volume is limited to the internal volume of the needle. Not autoclavable. Needle gauge is determined by the syringe volume and are not user-selectable. Removable needles are a Hamilton-specific design. The design allows the needles to seat precisely at the zero graduation mark of the syringe. Users can select the needle gauge, length, and point style to optimize the syringe for custom applications. This termination also allows for a removable needle without increasing the dead volume of the syringe and is ideal when there is a risk of the needle clogging. Autoclavable when disassembled. Repeated autoclaving will shorten syringe life. Needle Point Style: Point style 2 is a sharp, beveled, curved, non-coring needle point recommended for septum penetration.

  • Manufacturer: Hamilton
    Model: 1800

  • Volume Range (µL): 0 - 25
    Channels: SYRINGE

Description: Hamilton 1825 Large, RN Syringe, 22s Gauge, 250 µL, Each
Part Number: 84889

The 1800 series is the reinforced plunger version of the 1700 series syringe. Attached to the flange of the syringe is a removable blue syringe holder that prevents heat transfer, dispense inaccuracies and plunger blow outs. It also provides support to small volume plungers that are prone to bending during injection. Ideal for dispensing both liquids and gases. They have a precision-machined PTFE plunger tip which creates a leak-free seal. With the tight fit, the tip essentially wipes the interior of the syringe barrel free of sample. This feature is particularly useful with heterogeneous samples as it reduces the chance that a deposit will occur and cause the plunger to freeze. Fluid path is SST, borosilicate glass, and PTFE. Gas sterilizable. This series is ideal for dispensing volumes from 1μL up to 500μL. A variety of different terminations and needle options are available. Syringe Terminations: Cemented needles for low volume syringes are cemented into the glass syringe barrel at a point corresponding to the zero graduation mark. With this termination, dead volume is limited to the internal volume of the needle. Not autoclavable. Needle gauge is determined by the syringe volume and are not user-selectable. Removable needles are a Hamilton-specific design. The design allows the needles to seat precisely at the zero graduation mark of the syringe. Users can select the needle gauge, length, and point style to optimize the syringe for custom applications. This termination also allows for a removable needle without increasing the dead volume of the syringe and is ideal when there is a risk of the needle clogging. Autoclavable when disassembled. Repeated autoclaving will shorten syringe life. Needle Point Style: Point style 2 is a sharp, beveled, curved, non-coring needle point recommended for septum penetration.

  • Manufacturer: Hamilton
    Model: 1800

  • Volume Range (µL): 0 - 250
    Channels: SYRINGE

Description: Hamilton 1801 Small, RN Syringe, 26s Gauge, 10 µL, Each
Part Number: 84877

The 1800 series is the reinforced plunger version of the 1700 series syringe. Attached to the flange of the syringe is a removable blue syringe holder that prevents heat transfer, dispense inaccuracies and plunger blow outs. It also provides support to small volume plungers that are prone to bending during injection. Ideal for dispensing both liquids and gases. They have a precision-machined PTFE plunger tip which creates a leak-free seal. With the tight fit, the tip essentially wipes the interior of the syringe barrel free of sample. This feature is particularly useful with heterogeneous samples as it reduces the chance that a deposit will occur and cause the plunger to freeze. Fluid path is SST, borosilicate glass, and PTFE. Gas sterilizable. This series is ideal for dispensing volumes from 1μL up to 500μL. A variety of different terminations and needle options are available. Syringe Terminations: Cemented needles for low volume syringes are cemented into the glass syringe barrel at a point corresponding to the zero graduation mark. With this termination, dead volume is limited to the internal volume of the needle. Not autoclavable. Needle gauge is determined by the syringe volume and are not user-selectable. Removable needles are a Hamilton-specific design. The design allows the needles to seat precisely at the zero graduation mark of the syringe. Users can select the needle gauge, length, and point style to optimize the syringe for custom applications. This termination also allows for a removable needle without increasing the dead volume of the syringe and is ideal when there is a risk of the needle clogging. Autoclavable when disassembled. Repeated autoclaving will shorten syringe life. Needle Point Style: Point style 2 is a sharp, beveled, curved, non-coring needle point recommended for septum penetration.

  • Manufacturer: Hamilton
    Model: 1800

  • Volume Range (µL): 0 - 10
    Channels: SYRINGE

Description: Hamilton 1710 N, 22s Gauge, 100 µL, PT=2, Cemented Needle Syringe, Each
Part Number: 81000

These syringes are the Gastight® version of the original 700 series syringes and are ideal for dispensing volumes from 1μL up to 500μL. Gastight® syringes are ideal for dispensing both liquids and gases and have a precision-machined PTFE plunger tip which creates a leak-free seal. With the tight fit, the tip essentially wipes the interior of the syringe barrel free of sample. This feature is particularly useful with heterogeneous samples as it reduces the chance that a deposit will occur and cause the plunger to freeze. Fluid path includes SST, borosilicate glass, and PTFE. Syringes are gas sterilizable. A variety of different terminations and needle point styles are available. Terminations include cemented needle, removable needle, luer tip, and PTFE luer lock. Syringe Terminations: Cemented needles for low volume syringes are cemented into the glass syringe barrel at a point corresponding to the zero graduation mark. With this termination, dead volume is limited to the internal volume of the needle. Not autoclavable. Needle gauge is determined by the syringe volume and are not user-selectable. Removable needles are a Hamilton-specific design. The design allows the needles to seat precisely at the zero graduation mark of the syringe. Users can select the needle gauge, length, and point style to optimize the syringe for custom applications. This termination allows for a removable needle without increasing the dead volume of the syringe and is ideal when there is a risk of the needle clogging. Autoclavable when disassembled. Repeated autoclaving will shorten syringe life. Luer tip needles are removable and fit over a ground glass hub which is tapered in the shape of a male luer. This termination will accept most hypodermic needles but was designed specifically for use with Hamilton Kel-F needles. This termination also increases the dead volume in the syringe, which may not be appropriate for some applications. Autoclavable to 115°C when disassembled. PTFE luer lock termination has a PTFE, male Luer taper with nickelplated brass locking hub for use with Kel-F needles, metal hub needles, and universal connectors. It is also used with Hamilton diluters/dispensers, OEM applications, and manual operations. The version with slots is used during the attachment to some instruments but does not effect the connection to needles. Not autoclavable (25mL and greater syringes). Needle Point Styles: Point style 2 is a sharp, beveled, curved, non-coring needle point recommended for septum penetration. Point style 3 is a blunt needle point for use with HPLC injection valves and for sample pipetting. Point style 5 is a conical needle with side port for penetration of septa, thin-gauged vinyls and plastics without coring.

  • Manufacturer: Hamilton
    Model: 1700

  • Volume Range (µL): 0 - 100
    Channels: SYRINGE

Description: Hamilton 1725 N, 22 Gauge, 250 µL, PT=3, Cemented Needle Syringe, Each
Part Number: 81185

These syringes are the Gastight® version of the original 700 series syringes and are ideal for dispensing volumes from 1μL up to 500μL. Gastight® syringes are ideal for dispensing both liquids and gases and have a precision-machined PTFE plunger tip which creates a leak-free seal. With the tight fit, the tip essentially wipes the interior of the syringe barrel free of sample. This feature is particularly useful with heterogeneous samples as it reduces the chance that a deposit will occur and cause the plunger to freeze. Fluid path includes SST, borosilicate glass, and PTFE. Syringes are gas sterilizable. A variety of different terminations and needle point styles are available. Terminations include cemented needle, removable needle, luer tip, and PTFE luer lock. Syringe Terminations: Cemented needles for low volume syringes are cemented into the glass syringe barrel at a point corresponding to the zero graduation mark. With this termination, dead volume is limited to the internal volume of the needle. Not autoclavable. Needle gauge is determined by the syringe volume and are not user-selectable. Removable needles are a Hamilton-specific design. The design allows the needles to seat precisely at the zero graduation mark of the syringe. Users can select the needle gauge, length, and point style to optimize the syringe for custom applications. This termination allows for a removable needle without increasing the dead volume of the syringe and is ideal when there is a risk of the needle clogging. Autoclavable when disassembled. Repeated autoclaving will shorten syringe life. Luer tip needles are removable and fit over a ground glass hub which is tapered in the shape of a male luer. This termination will accept most hypodermic needles but was designed specifically for use with Hamilton Kel-F needles. This termination also increases the dead volume in the syringe, which may not be appropriate for some applications. Autoclavable to 115°C when disassembled. PTFE luer lock termination has a PTFE, male Luer taper with nickelplated brass locking hub for use with Kel-F needles, metal hub needles, and universal connectors. It is also used with Hamilton diluters/dispensers, OEM applications, and manual operations. The version with slots is used during the attachment to some instruments but does not effect the connection to needles. Not autoclavable (25mL and greater syringes). Needle Point Styles: Point style 2 is a sharp, beveled, curved, non-coring needle point recommended for septum penetration. Point style 3 is a blunt needle point for use with HPLC injection valves and for sample pipetting. Point style 5 is a conical needle with side port for penetration of septa, thin-gauged vinyls and plastics without coring.

  • Manufacturer: Hamilton
    Model: 1700

  • Volume Range (µL): 0 - 100
    Channels: SYRINGE

Description: VWR Labmax Basic Dispenser, 2 - 10mL x 0.2mL
Part Number: 40000-064

Dispensers have a unique direct displacement piston system that is chemical-resistant and provides safe, smooth dispensing. Units are designed with a unique air purging system that prevents loss of reagents and eliminates dripping or splashing of media. An exclusive reagent guard valve prohibits accidental discharge and eliminates the need for capping the discharge tube when the dispenser is not in use. The volume adjustment knob allows quick and easy setting, and locks the volume into place. The discharge tube can be turned on a 360° swivel, allowing convenient dispensing and safe positioning over the reagent label. Dispensers disassemble easily for cleaning. Automatic calibration eliminates readjustment. Fully autoclavable to 121°C (250°F). Basic dispensers have a PTFE system for broad general use. Choose a PTFE-lined dispenser for applications using hydrofluoric acid or a glass-lined dispenser for use with organic solvents. Ordering Information: Bottle-top dispensers with a 33mm neck are supplied with 24/25mm, 28mm, 38mm, and 45mm adapters. Dispensers with a 45mm neck are supplied with 28mm, 32/33mm, and 38mm adapters. Additional adapters also available separately. Adapter set 40000-072 consists of four adapters: 24/25mm (which fits only dispensers with a 33mm neck), and 28mm, 32/32mm, and 45mm adapters (which fit any dispenser). Reservoir bottle not included.

  • Manufacturer: VWR Private Label
    Model: Labmax

  • Volume Range (µL): 2000 - 10000
    Channels: Dispenser