Filter By Pipettor Attributes

Model: 382

Type/Channels: 14

Max Volume:




Help

Manufacturers

[ALL]
3M
A AND D ENGINEERING
A. DAIGER
AGILENT TECHNOLOGIES
AURORA BIOMED
AXYGEN SCIENTIFIC
BECKMAN COULTER
BEL-ART
BIOHIT
BIOTEK
BIOTIX
BRANDTECH SCIENTIFIC
CAPP
CLAY ADAMS
COLE PARMER
CORNING
DENVILLE SCIENTIFIC
DRUMMOND
DYNMAIC DEVICES
EPPENDORF
EXCALIBUR LABS
EXTRAGENE
GILSON
GLOBE SCIENTIFIC
HACH
HAMAMATSU
HAMILTON COMPANY
HELENA LABS
JENCONS
LABNET INTERNATIONAL
LAKE CHARLES
METTLER (ANACHEM)
MOLECULAR DEVICES
NATIONAL SCIENTIFIC SUPPLY
NICHIRYO/OXFORD
PERKIN ELMER
PHENIX
PROGROUP (WELLPRO)
PROTODYNE
QIAGEN
QORPAK
RAININ
RICE LAKE
RITTER
SGE
SILOGEX
STOCKWELL SCIENTIFIC
TECAN AG
THERMO FINNPIPETTE
THERMO FISHER
THERMO MATRIX
TITERTEK
ULSTER SCIENTIFIC INC.
USA SCIENTIFIC PLASTICS
VISTALAB TECHNOLOGIES
VOLAC
VWR INTERNATIONAL
WHEATON/SOCOREX
WILKEM SCIENTIFIC
WORLD PRECISION INSTRUMENTS

 
 

Pipettors

Find the best deals on pipettors at the Lab Procurement Services store!
If it's not in our catalog, click "Get a Quote" to request pricing.

Records Found: 2974

Sort by: Price High   Price Low   Part Number   Description   Reset Sorting

Page: First Previous ... 246 247 248 249 250  ... Next Last 

Description: Hamilton 600 Series, 5µL, 2-Part Plunger, EA
Part Number: 60373-361

The 600 series syringes are a rugged, durable, and long lasting half-stroke version of the original 700 series syringes. They have a reinforced plunger which prevents plunger bending. Each plunger is individually fitted to the glass barrel and cannot be interchanged between syringes. This series of syringes is ideal for dispensing volumes from 0.25μL up to 5μL. The 600 series is often used in applications that require one-handed operation because of the short stroke length and the reinforced plunger. Fluid path includes SST and borosilicate glass. Syringe Termination: Needles are removable and are a Hamilton-specific design. The design allows the needles to seat precisely at the zero graduation mark of the syringe. This termination also allows for a removable needle without increasing the dead volume of the syringe and is ideal when there is a risk of the needle clogging. Autoclavable when disassembled. Gas sterilizable. Repeated autoclaving will shorten syringe life. Needle Point Style: Point style 3 is a blunt needle point for use with HPLC injection valves and for sample pipetting. The 600 series syringes are a rugged, durable, and long lasting half-stroke version of the original 700 series syringes. They have a reinforced plunger which prevents plunger bending. Each plunger is individually fitted to the glass barrel and cannot be interchanged between syringes. This series of syringes is ideal for dispensing volumes from 0.25μL up to 5μL. The 600 series is often used in applications that require one-handed operation because of the short stroke length and the reinforced plunger. Fluid path includes SST and borosilicate glass. Syringe Termination: Needles are removable and are a Hamilton-specific design. The design allows the needles to seat precisely at the zero graduation mark of the syringe. This termination also allows for a removable needle without increasing the dead volume of the syringe and is ideal when there is a risk of the needle clogging. Autoclavable when disassembled. Gas sterilizable. Repeated autoclaving will shorten syringe life. Needle Point Style: Point style 3 is a blunt needle point for use with HPLC injection valves and for sample pipetting.

  • Manufacturer: Hamilton
    Model: 600

  • Volume Range (µL): 0 - 5
    Channels: SYRINGE

Description: Hamilton 1801 N Syringe, Cemented Needle, 16s Gauge, 10 µL, Each
Part Number: 84875

The 1800 series is the reinforced plunger version of the 1700 series syringe. Attached to the flange of the syringe is a removable blue syringe holder that prevents heat transfer, dispense inaccuracies and plunger blow outs. It also provides support to small volume plungers that are prone to bending during injection. Ideal for dispensing both liquids and gases. They have a precision-machined PTFE plunger tip which creates a leak-free seal. With the tight fit, the tip essentially wipes the interior of the syringe barrel free of sample. This feature is particularly useful with heterogeneous samples as it reduces the chance that a deposit will occur and cause the plunger to freeze. Fluid path is SST, borosilicate glass, and PTFE. Gas sterilizable. This series is ideal for dispensing volumes from 1μL up to 500μL. A variety of different terminations and needle options are available. Syringe Terminations: Cemented needles for low volume syringes are cemented into the glass syringe barrel at a point corresponding to the zero graduation mark. With this termination, dead volume is limited to the internal volume of the needle. Not autoclavable. Needle gauge is determined by the syringe volume and are not user-selectable. Removable needles are a Hamilton-specific design. The design allows the needles to seat precisely at the zero graduation mark of the syringe. Users can select the needle gauge, length, and point style to optimize the syringe for custom applications. This termination also allows for a removable needle without increasing the dead volume of the syringe and is ideal when there is a risk of the needle clogging. Autoclavable when disassembled. Repeated autoclaving will shorten syringe life. Needle Point Style: Point style 2 is a sharp, beveled, curved, non-coring needle point recommended for septum penetration.

  • Manufacturer: Hamilton
    Model: 1800

  • Volume Range (µL): 0 - 10
    Channels: SYRINGE

Description: Hamilton 1825 N Syringe, Cemented Needle, 22s Gauge, 250 µL, Each
Part Number: 84887

The 1800 series is the reinforced plunger version of the 1700 series syringe. Attached to the flange of the syringe is a removable blue syringe holder that prevents heat transfer, dispense inaccuracies and plunger blow outs. It also provides support to small volume plungers that are prone to bending during injection. Ideal for dispensing both liquids and gases. They have a precision-machined PTFE plunger tip which creates a leak-free seal. With the tight fit, the tip essentially wipes the interior of the syringe barrel free of sample. This feature is particularly useful with heterogeneous samples as it reduces the chance that a deposit will occur and cause the plunger to freeze. Fluid path is SST, borosilicate glass, and PTFE. Gas sterilizable. This series is ideal for dispensing volumes from 1μL up to 500μL. A variety of different terminations and needle options are available. Syringe Terminations: Cemented needles for low volume syringes are cemented into the glass syringe barrel at a point corresponding to the zero graduation mark. With this termination, dead volume is limited to the internal volume of the needle. Not autoclavable. Needle gauge is determined by the syringe volume and are not user-selectable. Removable needles are a Hamilton-specific design. The design allows the needles to seat precisely at the zero graduation mark of the syringe. Users can select the needle gauge, length, and point style to optimize the syringe for custom applications. This termination also allows for a removable needle without increasing the dead volume of the syringe and is ideal when there is a risk of the needle clogging. Autoclavable when disassembled. Repeated autoclaving will shorten syringe life. Needle Point Style: Point style 2 is a sharp, beveled, curved, non-coring needle point recommended for septum penetration.

  • Manufacturer: Hamilton
    Model: 1800

  • Volume Range (µL): 0 - 250
    Channels: SYRINGE

Description: Hamilton 1810 N Syringe, Cemented Needle, 22s Gauge, 100 µL, Each
Part Number: 84884

The 1800 series is the reinforced plunger version of the 1700 series syringe. Attached to the flange of the syringe is a removable blue syringe holder that prevents heat transfer, dispense inaccuracies and plunger blow outs. It also provides support to small volume plungers that are prone to bending during injection. Ideal for dispensing both liquids and gases. They have a precision-machined PTFE plunger tip which creates a leak-free seal. With the tight fit, the tip essentially wipes the interior of the syringe barrel free of sample. This feature is particularly useful with heterogeneous samples as it reduces the chance that a deposit will occur and cause the plunger to freeze. Fluid path is SST, borosilicate glass, and PTFE. Gas sterilizable. This series is ideal for dispensing volumes from 1μL up to 500μL. A variety of different terminations and needle options are available. Syringe Terminations: Cemented needles for low volume syringes are cemented into the glass syringe barrel at a point corresponding to the zero graduation mark. With this termination, dead volume is limited to the internal volume of the needle. Not autoclavable. Needle gauge is determined by the syringe volume and are not user-selectable. Removable needles are a Hamilton-specific design. The design allows the needles to seat precisely at the zero graduation mark of the syringe. Users can select the needle gauge, length, and point style to optimize the syringe for custom applications. This termination also allows for a removable needle without increasing the dead volume of the syringe and is ideal when there is a risk of the needle clogging. Autoclavable when disassembled. Repeated autoclaving will shorten syringe life. Needle Point Style: Point style 2 is a sharp, beveled, curved, non-coring needle point recommended for septum penetration.

  • Manufacturer: Hamilton
    Model: 1800

  • Volume Range (µL): 0 - 100
    Channels: SYRINGE

Description: Hamilton 1802 N Syringe, Cemented Needle, 22s Gauge, 25 µL, Each
Part Number: 84878

The 1800 series is the reinforced plunger version of the 1700 series syringe. Attached to the flange of the syringe is a removable blue syringe holder that prevents heat transfer, dispense inaccuracies and plunger blow outs. It also provides support to small volume plungers that are prone to bending during injection. Ideal for dispensing both liquids and gases. They have a precision-machined PTFE plunger tip which creates a leak-free seal. With the tight fit, the tip essentially wipes the interior of the syringe barrel free of sample. This feature is particularly useful with heterogeneous samples as it reduces the chance that a deposit will occur and cause the plunger to freeze. Fluid path is SST, borosilicate glass, and PTFE. Gas sterilizable. This series is ideal for dispensing volumes from 1μL up to 500μL. A variety of different terminations and needle options are available. Syringe Terminations: Cemented needles for low volume syringes are cemented into the glass syringe barrel at a point corresponding to the zero graduation mark. With this termination, dead volume is limited to the internal volume of the needle. Not autoclavable. Needle gauge is determined by the syringe volume and are not user-selectable. Removable needles are a Hamilton-specific design. The design allows the needles to seat precisely at the zero graduation mark of the syringe. Users can select the needle gauge, length, and point style to optimize the syringe for custom applications. This termination also allows for a removable needle without increasing the dead volume of the syringe and is ideal when there is a risk of the needle clogging. Autoclavable when disassembled. Repeated autoclaving will shorten syringe life. Needle Point Style: Point style 2 is a sharp, beveled, curved, non-coring needle point recommended for septum penetration.

  • Manufacturer: Hamilton
    Model: 1800

  • Volume Range (µL): 0 - 25
    Channels: SYRINGE

Description: Hamilton 1805 N Syringe, Cemented Needle, 22s Gauge, 50 µL, Each
Part Number: 84881

The 1800 series is the reinforced plunger version of the 1700 series syringe. Attached to the flange of the syringe is a removable blue syringe holder that prevents heat transfer, dispense inaccuracies and plunger blow outs. It also provides support to small volume plungers that are prone to bending during injection. Ideal for dispensing both liquids and gases. They have a precision-machined PTFE plunger tip which creates a leak-free seal. With the tight fit, the tip essentially wipes the interior of the syringe barrel free of sample. This feature is particularly useful with heterogeneous samples as it reduces the chance that a deposit will occur and cause the plunger to freeze. Fluid path is SST, borosilicate glass, and PTFE. Gas sterilizable. This series is ideal for dispensing volumes from 1μL up to 500μL. A variety of different terminations and needle options are available. Syringe Terminations: Cemented needles for low volume syringes are cemented into the glass syringe barrel at a point corresponding to the zero graduation mark. With this termination, dead volume is limited to the internal volume of the needle. Not autoclavable. Needle gauge is determined by the syringe volume and are not user-selectable. Removable needles are a Hamilton-specific design. The design allows the needles to seat precisely at the zero graduation mark of the syringe. Users can select the needle gauge, length, and point style to optimize the syringe for custom applications. This termination also allows for a removable needle without increasing the dead volume of the syringe and is ideal when there is a risk of the needle clogging. Autoclavable when disassembled. Repeated autoclaving will shorten syringe life. Needle Point Style: Point style 2 is a sharp, beveled, curved, non-coring needle point recommended for septum penetration.

  • Manufacturer: Hamilton
    Model: 1800

  • Volume Range (µL): 0 - 50
    Channels: SYRINGE

Description: Hamilton 1805 Small, RN Syringe, 22s Gauge, 50 µL, Each
Part Number: 84883

The 1800 series is the reinforced plunger version of the 1700 series syringe. Attached to the flange of the syringe is a removable blue syringe holder that prevents heat transfer, dispense inaccuracies and plunger blow outs. It also provides support to small volume plungers that are prone to bending during injection. Ideal for dispensing both liquids and gases. They have a precision-machined PTFE plunger tip which creates a leak-free seal. With the tight fit, the tip essentially wipes the interior of the syringe barrel free of sample. This feature is particularly useful with heterogeneous samples as it reduces the chance that a deposit will occur and cause the plunger to freeze. Fluid path is SST, borosilicate glass, and PTFE. Gas sterilizable. This series is ideal for dispensing volumes from 1μL up to 500μL. A variety of different terminations and needle options are available. Syringe Terminations: Cemented needles for low volume syringes are cemented into the glass syringe barrel at a point corresponding to the zero graduation mark. With this termination, dead volume is limited to the internal volume of the needle. Not autoclavable. Needle gauge is determined by the syringe volume and are not user-selectable. Removable needles are a Hamilton-specific design. The design allows the needles to seat precisely at the zero graduation mark of the syringe. Users can select the needle gauge, length, and point style to optimize the syringe for custom applications. This termination also allows for a removable needle without increasing the dead volume of the syringe and is ideal when there is a risk of the needle clogging. Autoclavable when disassembled. Repeated autoclaving will shorten syringe life. Needle Point Style: Point style 2 is a sharp, beveled, curved, non-coring needle point recommended for septum penetration.

  • Manufacturer: Hamilton
    Model: 1800

  • Volume Range (µL): 0 - 50
    Channels: SYRINGE