Filter By Pipettor Attributes

Model: 382

Type/Channels: 14

Max Volume:




Help

Manufacturers

[ALL]
3M
A AND D ENGINEERING
A. DAIGER
AGILENT TECHNOLOGIES
AURORA BIOMED
AXYGEN SCIENTIFIC
BECKMAN COULTER
BEL-ART
BIOHIT
BIOTEK
BIOTIX
BRANDTECH SCIENTIFIC
CAPP
CLAY ADAMS
COLE PARMER
CORNING
DENVILLE SCIENTIFIC
DRUMMOND
DYNMAIC DEVICES
EPPENDORF
EXCALIBUR LABS
EXTRAGENE
GILSON
GLOBE SCIENTIFIC
HACH
HAMAMATSU
HAMILTON COMPANY
HELENA LABS
JENCONS
LABNET INTERNATIONAL
LAKE CHARLES
METTLER (ANACHEM)
MOLECULAR DEVICES
NATIONAL SCIENTIFIC SUPPLY
NICHIRYO/OXFORD
PERKIN ELMER
PHENIX
PROGROUP (WELLPRO)
PROTODYNE
QIAGEN
QORPAK
RAININ
RICE LAKE
RITTER
SGE
SILOGEX
STOCKWELL SCIENTIFIC
TECAN AG
THERMO FINNPIPETTE
THERMO FISHER
THERMO MATRIX
TITERTEK
ULSTER SCIENTIFIC INC.
USA SCIENTIFIC PLASTICS
VISTALAB TECHNOLOGIES
VOLAC
VWR INTERNATIONAL
WHEATON/SOCOREX
WILKEM SCIENTIFIC
WORLD PRECISION INSTRUMENTS

 
 

Pipettors

Find the best deals on pipettors at the Lab Procurement Services store!
If it's not in our catalog, click "Get a Quote" to request pricing.

Records Found: 2974

Sort by: Price High   Price Low   Part Number   Description   Reset Sorting

Page: First Previous ... 46 47 48 49 50  ... Next Last 

Description: BrandTech Dispensette III Analog Adjustable Bottle-Top Dispenser, 0.05-.5 mL x0.1 mL
Part Number: 4701100

These bottle-top dispensers are safe, reliable, and easy to use. Ideal for dispensing most acids, bases, saline solutions, and many solvents. The floating piston design provides smooth, one-handed operation, and eliminates polymer seal wear, for minimal service downtime. Dispensers can be directly fitted to standard GL45 bottles, or can be fitted to most common reagent bottles using the supplied adapters and telescoping filling tube, which eliminates poured transfer. The threaded safety cap removes easily, with or without gloves. Choose from adjustable digital or analog models, in addition to fixed volume models. Easy Calibration™ digital models allow calibration adjustments in seconds without tools. SafetyPrime™ recirculation valve models reduce spurting during priming, help protect against inadvertent dispensing, and conserve valuable solvents. Valve block rotates 360°, allowing bottle label to always face the user. Optional, flexible discharge tube can be moved easily over a series of vessels, simplifying serial dispensing of scintillation fluid and other liquids. The discharge tube has a safety handle that reduces the risk of chemical splash from tube recoil. Optional remote dispensing system allows accurate dispensing from unpressurized drums and bulk refills. The dispenser may then be mounted as far as 10m (30') away from the container. Features a quick-release connector and an integral filter. NOWPak® adapter allows the use of economical and ecological NOWPak® bulk containers. Caution: This dispenser should never be used with hydrofluoric (HF) acid, sodium azide, or chemicals incompatible with any of the materials of the flowpath (borosilicate glass, PFA, FEP, ETFE, PTFE, alumina ceramic, and platinum-iridium alloy). To dispense concentrated acids, fuming acids, tetrahydrofuran (THF), peroxides, or chlorinated and fluorinated solvents, use the Dispensette organic dispenser (see 72888-010 series). To dispense hydrofluoric acid, use the Dispensette HF dispenser (see 47746-470 series). Ordering Information: Manufacturer’s one-year warranty. Supplied with calibration certificate, operating manual, one discharge tube, one filling tube, valve mounting/calibration tool, and polypropylene adapters. Dispensers with maximum volume of 10mL or less include 24, 28, 33, and 38mm adapters; 2.5–25mL and 5–50mL dispensers include 28, 33, and 38mm adapters; 10–100mL dispensers include 33 and 38mm adapters.

  • Manufacturer: Brandtech
    Model: Dispensette III Analog

  • Volume Range (µL): 50 - 500
    Channels: Dispenser

Description: BrandTech Dispensette III Analog Adjustable Bottle-Top Dispenser, 0.2-2 mL x0.05 mL
Part Number: 4701120

These bottle-top dispensers are safe, reliable, and easy to use. Ideal for dispensing most acids, bases, saline solutions, and many solvents. The floating piston design provides smooth, one-handed operation, and eliminates polymer seal wear, for minimal service downtime. Dispensers can be directly fitted to standard GL45 bottles, or can be fitted to most common reagent bottles using the supplied adapters and telescoping filling tube, which eliminates poured transfer. The threaded safety cap removes easily, with or without gloves. Choose from adjustable digital or analog models, in addition to fixed volume models. Easy Calibration™ digital models allow calibration adjustments in seconds without tools. SafetyPrime™ recirculation valve models reduce spurting during priming, help protect against inadvertent dispensing, and conserve valuable solvents. Valve block rotates 360°, allowing bottle label to always face the user. Optional, flexible discharge tube can be moved easily over a series of vessels, simplifying serial dispensing of scintillation fluid and other liquids. The discharge tube has a safety handle that reduces the risk of chemical splash from tube recoil. Optional remote dispensing system allows accurate dispensing from unpressurized drums and bulk refills. The dispenser may then be mounted as far as 10m (30') away from the container. Features a quick-release connector and an integral filter. NOWPak® adapter allows the use of economical and ecological NOWPak® bulk containers. Caution: This dispenser should never be used with hydrofluoric (HF) acid, sodium azide, or chemicals incompatible with any of the materials of the flowpath (borosilicate glass, PFA, FEP, ETFE, PTFE, alumina ceramic, and platinum-iridium alloy). To dispense concentrated acids, fuming acids, tetrahydrofuran (THF), peroxides, or chlorinated and fluorinated solvents, use the Dispensette organic dispenser (see 72888-010 series). To dispense hydrofluoric acid, use the Dispensette HF dispenser (see 47746-470 series). Ordering Information: Manufacturer’s one-year warranty. Supplied with calibration certificate, operating manual, one discharge tube, one filling tube, valve mounting/calibration tool, and polypropylene adapters. Dispensers with maximum volume of 10mL or less include 24, 28, 33, and 38mm adapters; 2.5–25mL and 5–50mL dispensers include 28, 33, and 38mm adapters; 10–100mL dispensers include 33 and 38mm adapters.

  • Manufacturer: Brandtech
    Model: Dispensette III Analog

  • Volume Range (µL): 200 - 2000
    Channels: Dispenser

Description: BrandTech Dispensette III Analog Adjustable Bottle-Top Dispenser, 0.5-5 mL x0.1 mL
Part Number: 4701130

These bottle-top dispensers are safe, reliable, and easy to use. Ideal for dispensing most acids, bases, saline solutions, and many solvents. The floating piston design provides smooth, one-handed operation, and eliminates polymer seal wear, for minimal service downtime. Dispensers can be directly fitted to standard GL45 bottles, or can be fitted to most common reagent bottles using the supplied adapters and telescoping filling tube, which eliminates poured transfer. The threaded safety cap removes easily, with or without gloves. Choose from adjustable digital or analog models, in addition to fixed volume models. Easy Calibration™ digital models allow calibration adjustments in seconds without tools. SafetyPrime™ recirculation valve models reduce spurting during priming, help protect against inadvertent dispensing, and conserve valuable solvents. Valve block rotates 360°, allowing bottle label to always face the user. Optional, flexible discharge tube can be moved easily over a series of vessels, simplifying serial dispensing of scintillation fluid and other liquids. The discharge tube has a safety handle that reduces the risk of chemical splash from tube recoil. Optional remote dispensing system allows accurate dispensing from unpressurized drums and bulk refills. The dispenser may then be mounted as far as 10m (30') away from the container. Features a quick-release connector and an integral filter. NOWPak® adapter allows the use of economical and ecological NOWPak® bulk containers. Caution: This dispenser should never be used with hydrofluoric (HF) acid, sodium azide, or chemicals incompatible with any of the materials of the flowpath (borosilicate glass, PFA, FEP, ETFE, PTFE, alumina ceramic, and platinum-iridium alloy). To dispense concentrated acids, fuming acids, tetrahydrofuran (THF), peroxides, or chlorinated and fluorinated solvents, use the Dispensette organic dispenser (see 72888-010 series). To dispense hydrofluoric acid, use the Dispensette HF dispenser (see 47746-470 series). Ordering Information: Manufacturer’s one-year warranty. Supplied with calibration certificate, operating manual, one discharge tube, one filling tube, valve mounting/calibration tool, and polypropylene adapters. Dispensers with maximum volume of 10mL or less include 24, 28, 33, and 38mm adapters; 2.5–25mL and 5–50mL dispensers include 28, 33, and 38mm adapters; 10–100mL dispensers include 33 and 38mm adapters.

  • Manufacturer: Brandtech
    Model: Dispensette III Analog

  • Volume Range (µL): 500 - 5000
    Channels: Dispenser

Description: Hamilton 1705 Small N, 22 Gauge, 50 µL, PT=3, Cemented Needle Syringe, Each
Part Number: 80985

These syringes are the Gastight® version of the original 700 series syringes and are ideal for dispensing volumes from 1μL up to 500μL. Gastight® syringes are ideal for dispensing both liquids and gases and have a precision-machined PTFE plunger tip which creates a leak-free seal. With the tight fit, the tip essentially wipes the interior of the syringe barrel free of sample. This feature is particularly useful with heterogeneous samples as it reduces the chance that a deposit will occur and cause the plunger to freeze. Fluid path includes SST, borosilicate glass, and PTFE. Syringes are gas sterilizable. A variety of different terminations and needle point styles are available. Terminations include cemented needle, removable needle, luer tip, and PTFE luer lock. Syringe Terminations: Cemented needles for low volume syringes are cemented into the glass syringe barrel at a point corresponding to the zero graduation mark. With this termination, dead volume is limited to the internal volume of the needle. Not autoclavable. Needle gauge is determined by the syringe volume and are not user-selectable. Removable needles are a Hamilton-specific design. The design allows the needles to seat precisely at the zero graduation mark of the syringe. Users can select the needle gauge, length, and point style to optimize the syringe for custom applications. This termination allows for a removable needle without increasing the dead volume of the syringe and is ideal when there is a risk of the needle clogging. Autoclavable when disassembled. Repeated autoclaving will shorten syringe life. Luer tip needles are removable and fit over a ground glass hub which is tapered in the shape of a male luer. This termination will accept most hypodermic needles but was designed specifically for use with Hamilton Kel-F needles. This termination also increases the dead volume in the syringe, which may not be appropriate for some applications. Autoclavable to 115°C when disassembled. PTFE luer lock termination has a PTFE, male Luer taper with nickelplated brass locking hub for use with Kel-F needles, metal hub needles, and universal connectors. It is also used with Hamilton diluters/dispensers, OEM applications, and manual operations. The version with slots is used during the attachment to some instruments but does not effect the connection to needles. Not autoclavable (25mL and greater syringes). Needle Point Styles: Point style 2 is a sharp, beveled, curved, non-coring needle point recommended for septum penetration. Point style 3 is a blunt needle point for use with HPLC injection valves and for sample pipetting. Point style 5 is a conical needle with side port for penetration of septa, thin-gauged vinyls and plastics without coring.

  • Manufacturer: Hamilton
    Model: 1700

  • Volume Range (µL): 0 - 100
    Channels: SYRINGE

Description: Hamilton 175 N, 23s Gauge, 5 µL, PT=AS, Cemented Needle Syringe, Each
Part Number: 80074

These syringes are the Gastight® version of the original 700 series syringes and are ideal for dispensing volumes from 1μL up to 500μL. Gastight® syringes are ideal for dispensing both liquids and gases and have a precision-machined PTFE plunger tip which creates a leak-free seal. With the tight fit, the tip essentially wipes the interior of the syringe barrel free of sample. This feature is particularly useful with heterogeneous samples as it reduces the chance that a deposit will occur and cause the plunger to freeze. Fluid path includes SST, borosilicate glass, and PTFE. Syringes are gas sterilizable. A variety of different terminations and needle point styles are available. Terminations include cemented needle, removable needle, luer tip, and PTFE luer lock. Syringe Terminations: Cemented needles for low volume syringes are cemented into the glass syringe barrel at a point corresponding to the zero graduation mark. With this termination, dead volume is limited to the internal volume of the needle. Not autoclavable. Needle gauge is determined by the syringe volume and are not user-selectable. Removable needles are a Hamilton-specific design. The design allows the needles to seat precisely at the zero graduation mark of the syringe. Users can select the needle gauge, length, and point style to optimize the syringe for custom applications. This termination allows for a removable needle without increasing the dead volume of the syringe and is ideal when there is a risk of the needle clogging. Autoclavable when disassembled. Repeated autoclaving will shorten syringe life. Luer tip needles are removable and fit over a ground glass hub which is tapered in the shape of a male luer. This termination will accept most hypodermic needles but was designed specifically for use with Hamilton Kel-F needles. This termination also increases the dead volume in the syringe, which may not be appropriate for some applications. Autoclavable to 115°C when disassembled. PTFE luer lock termination has a PTFE, male Luer taper with nickelplated brass locking hub for use with Kel-F needles, metal hub needles, and universal connectors. It is also used with Hamilton diluters/dispensers, OEM applications, and manual operations. The version with slots is used during the attachment to some instruments but does not effect the connection to needles. Not autoclavable (25mL and greater syringes). Needle Point Styles: Point style 2 is a sharp, beveled, curved, non-coring needle point recommended for septum penetration. Point style 3 is a blunt needle point for use with HPLC injection valves and for sample pipetting. Point style 5 is a conical needle with side port for penetration of septa, thin-gauged vinyls and plastics without coring.

  • Manufacturer: Hamilton
    Model: 1700

  • Volume Range (µL): 0 - 100
    Channels: SYRINGE

Description: 3M Electronic Pipettor II, 5mL
Part Number: 6503

These pipettors provide high accuracy and precision handling for pipetting volumes of liquids.

  • Manufacturer: 3M
    Model: 3M Pipettor II

  • Volume Range (µL): 1000 - 5000
    Channels: 1

Description: Nichiryo Dispet Bottletop Dispenser, 0.2 - 1ML
Part Number: DP-1

Can be attached directly to all standard reagent bottles. Comes with an adapter (ø22mm) for direct attachment to smaller reagent bottles. (100ml>) (not DP-5 and DP-10) Light weight and compact design for easy handling. Liquid contact parts are chemically resistant material. Extra tube (220mm) is included and can be cut into a more convenient size.

  • Manufacturer: Nichiryo
    Model: Dispet

  • Volume Range (µL): 200 - 1000
    Channels: Dispenser