Filter By Pipettor Attributes

Model: 382

Type/Channels: 14

Max Volume:




Help

Manufacturers

[ALL]
3M
A AND D ENGINEERING
A. DAIGER
AGILENT TECHNOLOGIES
AURORA BIOMED
AXYGEN SCIENTIFIC
BECKMAN COULTER
BEL-ART
BIOHIT
BIOTEK
BIOTIX
BRANDTECH SCIENTIFIC
CAPP
CLAY ADAMS
COLE PARMER
CORNING
DENVILLE SCIENTIFIC
DRUMMOND
DYNMAIC DEVICES
EPPENDORF
EXCALIBUR LABS
EXTRAGENE
GILSON
GLOBE SCIENTIFIC
HACH
HAMAMATSU
HAMILTON COMPANY
HELENA LABS
JENCONS
LABNET INTERNATIONAL
LAKE CHARLES
METTLER (ANACHEM)
MOLECULAR DEVICES
NATIONAL SCIENTIFIC SUPPLY
NICHIRYO/OXFORD
PERKIN ELMER
PHENIX
PROGROUP (WELLPRO)
PROTODYNE
QIAGEN
QORPAK
RAININ
RICE LAKE
RITTER
SGE
SILOGEX
STOCKWELL SCIENTIFIC
TECAN AG
THERMO FINNPIPETTE
THERMO FISHER
THERMO MATRIX
TITERTEK
ULSTER SCIENTIFIC INC.
USA SCIENTIFIC PLASTICS
VISTALAB TECHNOLOGIES
VOLAC
VWR INTERNATIONAL
WHEATON/SOCOREX
WILKEM SCIENTIFIC
WORLD PRECISION INSTRUMENTS

 
 

Pipettors

Find the best deals on pipettors at the Lab Procurement Services store!
If it's not in our catalog, click "Get a Quote" to request pricing.

Records Found: 2974

Sort by: Price High   Price Low   Part Number   Description   Reset Sorting

Page: First Previous ... 221 222 223 224 225  ... Next Last 

Description: Hamilton 1702 N, 22 Gauge, 25 µL, PT=3, Cemented Needle Syringe, Each
Part Number: 80285

These syringes are the Gastight® version of the original 700 series syringes and are ideal for dispensing volumes from 1μL up to 500μL. Gastight® syringes are ideal for dispensing both liquids and gases and have a precision-machined PTFE plunger tip which creates a leak-free seal. With the tight fit, the tip essentially wipes the interior of the syringe barrel free of sample. This feature is particularly useful with heterogeneous samples as it reduces the chance that a deposit will occur and cause the plunger to freeze. Fluid path includes SST, borosilicate glass, and PTFE. Syringes are gas sterilizable. A variety of different terminations and needle point styles are available. Terminations include cemented needle, removable needle, luer tip, and PTFE luer lock. Syringe Terminations: Cemented needles for low volume syringes are cemented into the glass syringe barrel at a point corresponding to the zero graduation mark. With this termination, dead volume is limited to the internal volume of the needle. Not autoclavable. Needle gauge is determined by the syringe volume and are not user-selectable. Removable needles are a Hamilton-specific design. The design allows the needles to seat precisely at the zero graduation mark of the syringe. Users can select the needle gauge, length, and point style to optimize the syringe for custom applications. This termination allows for a removable needle without increasing the dead volume of the syringe and is ideal when there is a risk of the needle clogging. Autoclavable when disassembled. Repeated autoclaving will shorten syringe life. Luer tip needles are removable and fit over a ground glass hub which is tapered in the shape of a male luer. This termination will accept most hypodermic needles but was designed specifically for use with Hamilton Kel-F needles. This termination also increases the dead volume in the syringe, which may not be appropriate for some applications. Autoclavable to 115°C when disassembled. PTFE luer lock termination has a PTFE, male Luer taper with nickelplated brass locking hub for use with Kel-F needles, metal hub needles, and universal connectors. It is also used with Hamilton diluters/dispensers, OEM applications, and manual operations. The version with slots is used during the attachment to some instruments but does not effect the connection to needles. Not autoclavable (25mL and greater syringes). Needle Point Styles: Point style 2 is a sharp, beveled, curved, non-coring needle point recommended for septum penetration. Point style 3 is a blunt needle point for use with HPLC injection valves and for sample pipetting. Point style 5 is a conical needle with side port for penetration of septa, thin-gauged vinyls and plastics without coring.

  • Manufacturer: Hamilton
    Model: 1700

  • Volume Range (µL): 0 - 100
    Channels: SYRINGE

Description: Hamilton 1701 N, 26 Gauge, 10 µL, PT=3, Cemented Needle Syringe, Each
Part Number: 80085

These syringes are the Gastight® version of the original 700 series syringes and are ideal for dispensing volumes from 1μL up to 500μL. Gastight® syringes are ideal for dispensing both liquids and gases and have a precision-machined PTFE plunger tip which creates a leak-free seal. With the tight fit, the tip essentially wipes the interior of the syringe barrel free of sample. This feature is particularly useful with heterogeneous samples as it reduces the chance that a deposit will occur and cause the plunger to freeze. Fluid path includes SST, borosilicate glass, and PTFE. Syringes are gas sterilizable. A variety of different terminations and needle point styles are available. Terminations include cemented needle, removable needle, luer tip, and PTFE luer lock. Syringe Terminations: Cemented needles for low volume syringes are cemented into the glass syringe barrel at a point corresponding to the zero graduation mark. With this termination, dead volume is limited to the internal volume of the needle. Not autoclavable. Needle gauge is determined by the syringe volume and are not user-selectable. Removable needles are a Hamilton-specific design. The design allows the needles to seat precisely at the zero graduation mark of the syringe. Users can select the needle gauge, length, and point style to optimize the syringe for custom applications. This termination allows for a removable needle without increasing the dead volume of the syringe and is ideal when there is a risk of the needle clogging. Autoclavable when disassembled. Repeated autoclaving will shorten syringe life. Luer tip needles are removable and fit over a ground glass hub which is tapered in the shape of a male luer. This termination will accept most hypodermic needles but was designed specifically for use with Hamilton Kel-F needles. This termination also increases the dead volume in the syringe, which may not be appropriate for some applications. Autoclavable to 115°C when disassembled. PTFE luer lock termination has a PTFE, male Luer taper with nickelplated brass locking hub for use with Kel-F needles, metal hub needles, and universal connectors. It is also used with Hamilton diluters/dispensers, OEM applications, and manual operations. The version with slots is used during the attachment to some instruments but does not effect the connection to needles. Not autoclavable (25mL and greater syringes). Needle Point Styles: Point style 2 is a sharp, beveled, curved, non-coring needle point recommended for septum penetration. Point style 3 is a blunt needle point for use with HPLC injection valves and for sample pipetting. Point style 5 is a conical needle with side port for penetration of septa, thin-gauged vinyls and plastics without coring.

  • Manufacturer: Hamilton
    Model: 1700

  • Volume Range (µL): 0 - 100
    Channels: SYRINGE

Description: Hamilton 1710 N, 22s Gauge, 100 µL, PT=3, Cemented Needle Syringe, Each
Part Number: 81075

These syringes are the Gastight® version of the original 700 series syringes and are ideal for dispensing volumes from 1μL up to 500μL. Gastight® syringes are ideal for dispensing both liquids and gases and have a precision-machined PTFE plunger tip which creates a leak-free seal. With the tight fit, the tip essentially wipes the interior of the syringe barrel free of sample. This feature is particularly useful with heterogeneous samples as it reduces the chance that a deposit will occur and cause the plunger to freeze. Fluid path includes SST, borosilicate glass, and PTFE. Syringes are gas sterilizable. A variety of different terminations and needle point styles are available. Terminations include cemented needle, removable needle, luer tip, and PTFE luer lock. Syringe Terminations: Cemented needles for low volume syringes are cemented into the glass syringe barrel at a point corresponding to the zero graduation mark. With this termination, dead volume is limited to the internal volume of the needle. Not autoclavable. Needle gauge is determined by the syringe volume and are not user-selectable. Removable needles are a Hamilton-specific design. The design allows the needles to seat precisely at the zero graduation mark of the syringe. Users can select the needle gauge, length, and point style to optimize the syringe for custom applications. This termination allows for a removable needle without increasing the dead volume of the syringe and is ideal when there is a risk of the needle clogging. Autoclavable when disassembled. Repeated autoclaving will shorten syringe life. Luer tip needles are removable and fit over a ground glass hub which is tapered in the shape of a male luer. This termination will accept most hypodermic needles but was designed specifically for use with Hamilton Kel-F needles. This termination also increases the dead volume in the syringe, which may not be appropriate for some applications. Autoclavable to 115°C when disassembled. PTFE luer lock termination has a PTFE, male Luer taper with nickelplated brass locking hub for use with Kel-F needles, metal hub needles, and universal connectors. It is also used with Hamilton diluters/dispensers, OEM applications, and manual operations. The version with slots is used during the attachment to some instruments but does not effect the connection to needles. Not autoclavable (25mL and greater syringes). Needle Point Styles: Point style 2 is a sharp, beveled, curved, non-coring needle point recommended for septum penetration. Point style 3 is a blunt needle point for use with HPLC injection valves and for sample pipetting. Point style 5 is a conical needle with side port for penetration of septa, thin-gauged vinyls and plastics without coring.

  • Manufacturer: Hamilton
    Model: 1700

  • Volume Range (µL): 0 - 100
    Channels: SYRINGE

Description: Hamilton 1705 N, 22s Gauge, 50 µL, PT=3, Cemented Needle Syringe, Each
Part Number: 80975

These syringes are the Gastight® version of the original 700 series syringes and are ideal for dispensing volumes from 1μL up to 500μL. Gastight® syringes are ideal for dispensing both liquids and gases and have a precision-machined PTFE plunger tip which creates a leak-free seal. With the tight fit, the tip essentially wipes the interior of the syringe barrel free of sample. This feature is particularly useful with heterogeneous samples as it reduces the chance that a deposit will occur and cause the plunger to freeze. Fluid path includes SST, borosilicate glass, and PTFE. Syringes are gas sterilizable. A variety of different terminations and needle point styles are available. Terminations include cemented needle, removable needle, luer tip, and PTFE luer lock. Syringe Terminations: Cemented needles for low volume syringes are cemented into the glass syringe barrel at a point corresponding to the zero graduation mark. With this termination, dead volume is limited to the internal volume of the needle. Not autoclavable. Needle gauge is determined by the syringe volume and are not user-selectable. Removable needles are a Hamilton-specific design. The design allows the needles to seat precisely at the zero graduation mark of the syringe. Users can select the needle gauge, length, and point style to optimize the syringe for custom applications. This termination allows for a removable needle without increasing the dead volume of the syringe and is ideal when there is a risk of the needle clogging. Autoclavable when disassembled. Repeated autoclaving will shorten syringe life. Luer tip needles are removable and fit over a ground glass hub which is tapered in the shape of a male luer. This termination will accept most hypodermic needles but was designed specifically for use with Hamilton Kel-F needles. This termination also increases the dead volume in the syringe, which may not be appropriate for some applications. Autoclavable to 115°C when disassembled. PTFE luer lock termination has a PTFE, male Luer taper with nickelplated brass locking hub for use with Kel-F needles, metal hub needles, and universal connectors. It is also used with Hamilton diluters/dispensers, OEM applications, and manual operations. The version with slots is used during the attachment to some instruments but does not effect the connection to needles. Not autoclavable (25mL and greater syringes). Needle Point Styles: Point style 2 is a sharp, beveled, curved, non-coring needle point recommended for septum penetration. Point style 3 is a blunt needle point for use with HPLC injection valves and for sample pipetting. Point style 5 is a conical needle with side port for penetration of septa, thin-gauged vinyls and plastics without coring.

  • Manufacturer: Hamilton
    Model: 1700

  • Volume Range (µL): 0 - 100
    Channels: SYRINGE

Description: Hach Tensette Pipet, 1000 - 10,000uL
Part Number: 1970010

Perform routine laboratory pipetting quickly, economically, and accurately with Hach's automatic TenSette® Pipet. Two models dispense from 0.1 to 1 ml or from 1 to 10 ml in 0.1 or 1.0 ml increments, respectively. The pipet saves time, reduces glassware cleanup and assures accuracy. Set includes pipet, manual and 50 disposable tips.

  • Manufacturer: Hach
    Model: Tensette

  • Volume Range (µL): 1000 - 10000
    Channels: 1

Description: Excalibur 99 Micro-Varipet Single Channel 1-5µL
Part Number: 711A

Adjustable, gearless micro meter with locking ring. Air piston system working with 2-step operation. Stainless steel pistons with Teflon sealing. (Si O-ring on Jumbo size) Simple colour-coded finger buttons indicate capacity. Accuracy (H20, 20°C): 5~15 uL <2%; 20-5000 uL <1%. Utilizes disposable polypropylene tips. In addition to the standard sizes, Excalibur Laboratories also offers a larger 1 - 10000 microLitre Varipet. This high-capacity pipette utilizes our special D-Tips for increased accuracy.

  • Manufacturer: Excalibur Labs
    Model: Excalibur 99 Varipet

  • Volume Range (µL): 1 - 5
    Channels: 1

Description: Thermo Labsystems Finnpipette F2 12-Channel 5 -50µL
Part Number: 4662050

Finnpipette™ F2 multichannel pipettors offer outstanding accuracy and precision in laboratory based liquid dispensing procedures. These pipettors combine established Finnpipette™ features with state-of-the-art innovations to create a reliable and ergonomic high-performance device. Pipettors are equipped with an advanced volume gearing mechanism (AVG) designed to improve accuracy and precision. Each lightweight device offers remarkably smooth pipetting action. Pipettors are fully autoclavable and easy to service. An enlarged digit display improves ease of use, and color coding simplifies instrument selection.

  • Manufacturer: Finnpipette (Thermo)
    Model: F2 Multi-Channel

  • Volume Range (µL): 5 - 50
    Channels: 12