Filter By Pipettor Attributes

Model: 382

Type/Channels: 14

Max Volume:




Help

Manufacturers

[ALL]
3M
A AND D ENGINEERING
A. DAIGER
AGILENT TECHNOLOGIES
AURORA BIOMED
AXYGEN SCIENTIFIC
BECKMAN COULTER
BEL-ART
BIOHIT
BIOTEK
BIOTIX
BRANDTECH SCIENTIFIC
CAPP
CLAY ADAMS
COLE PARMER
CORNING
DENVILLE SCIENTIFIC
DRUMMOND
DYNMAIC DEVICES
EPPENDORF
EXCALIBUR LABS
EXTRAGENE
GILSON
GLOBE SCIENTIFIC
HACH
HAMAMATSU
HAMILTON COMPANY
HELENA LABS
JENCONS
LABNET INTERNATIONAL
LAKE CHARLES
METTLER (ANACHEM)
MOLECULAR DEVICES
NATIONAL SCIENTIFIC SUPPLY
NICHIRYO/OXFORD
PERKIN ELMER
PHENIX
PROGROUP (WELLPRO)
PROTODYNE
QIAGEN
QORPAK
RAININ
RICE LAKE
RITTER
SGE
SILOGEX
STOCKWELL SCIENTIFIC
TECAN AG
THERMO FINNPIPETTE
THERMO FISHER
THERMO MATRIX
TITERTEK
ULSTER SCIENTIFIC INC.
USA SCIENTIFIC PLASTICS
VISTALAB TECHNOLOGIES
VOLAC
VWR INTERNATIONAL
WHEATON/SOCOREX
WILKEM SCIENTIFIC
WORLD PRECISION INSTRUMENTS

 
 

Pipettors

Find the best deals on pipettors at the Lab Procurement Services store!
If it's not in our catalog, click "Get a Quote" to request pricing.

Records Found: 2974

Sort by: Price High   Price Low   Part Number   Description   Reset Sorting

Page: First Previous ... 156 157 158 159 160  ... Next Last 

Description: Biohit Single Channel Pipette, Adjustable Volume, 10–300µL
Part Number: LH-745061

The Sartorius Picus NxT pipettes are the most sophisticated and ergonomic electronic pipettes on the market. These exceptionally compact and lightweight pipettes have been designed to ease the user's workload and to protect from repetitive strain injury. The newest technology and fully electronic operation assure high accuracy and precision of the results. Picus NxT pipettes provide distinct advantages for highly regulated laboratories. Picus NxT pipettes offer the distinct advantage of compliance in strictly regulated laboratories, including a certificate of accredited 3-point calibration. It is RFID-enabled to support asset management. The superior design of Picus NxT devices, adopted from the award-winning Picus, provides maximum operating convenience. The superior technology, electronic brake, and piston control system ensures accurate and precise pipetting results. By guiding pipetting steps, the unique plate tracker increases reliability in correctly filling microwell plates. The pipette's repetitive blow-out function facilitates dispensing of the very last sample droplets, even with viscous liquids.

  • Manufacturer: Biohit
    Model: Picus NxT Electronic

  • Volume Range (µL): 10 - 300
    Channels: 1

Description: BrandTech Transferpette Single Channel 10 - 100µL
Part Number: 704174

Designed to fit the contours of the human hand, the hook-shaped handle and side-mounted pipetting key of these pipettors combine to create an ergonomic instrument that minimizes the discomfort of repetitive pipetting. Light in weight, these reliable tools

  • Manufacturer: Brandtech
    Model: Transferpette

  • Volume Range (µL): 10 - 100
    Channels: 1

Description: BrandTech Transferpette Single Channel 10 - 100µL
Part Number: 704180

Designed to fit the contours of the human hand, the hook-shaped handle and side-mounted pipetting key of these pipettors combine to create an ergonomic instrument that minimizes the discomfort of repetitive pipetting. Light in weight, these reliable tools

  • Manufacturer: Brandtech
    Model: Transferpette

  • Volume Range (µL): 10 - 100
    Channels: 1

Description: Biohit Single Channel Pipette, Adjustable Volume, 50–1000µL
Part Number: LH-745081

The Sartorius Picus NxT pipettes are the most sophisticated and ergonomic electronic pipettes on the market. These exceptionally compact and lightweight pipettes have been designed to ease the user's workload and to protect from repetitive strain injury. The newest technology and fully electronic operation assure high accuracy and precision of the results. Picus NxT pipettes provide distinct advantages for highly regulated laboratories. Picus NxT pipettes offer the distinct advantage of compliance in strictly regulated laboratories, including a certificate of accredited 3-point calibration. It is RFID-enabled to support asset management. The superior design of Picus NxT devices, adopted from the award-winning Picus, provides maximum operating convenience. The superior technology, electronic brake, and piston control system ensures accurate and precise pipetting results. By guiding pipetting steps, the unique plate tracker increases reliability in correctly filling microwell plates. The pipette's repetitive blow-out function facilitates dispensing of the very last sample droplets, even with viscous liquids.

  • Manufacturer: Biohit
    Model: Picus NxT Electronic

  • Volume Range (µL): 50 - 1000
    Channels: 1

Description: Biohit Single Channel Pipette, Adjustable Volume, 100–5000µL
Part Number: LH-745101

The Sartorius Picus NxT pipettes are the most sophisticated and ergonomic electronic pipettes on the market. These exceptionally compact and lightweight pipettes have been designed to ease the user's workload and to protect from repetitive strain injury. The newest technology and fully electronic operation assure high accuracy and precision of the results. Picus NxT pipettes provide distinct advantages for highly regulated laboratories. Picus NxT pipettes offer the distinct advantage of compliance in strictly regulated laboratories, including a certificate of accredited 3-point calibration. It is RFID-enabled to support asset management. The superior design of Picus NxT devices, adopted from the award-winning Picus, provides maximum operating convenience. The superior technology, electronic brake, and piston control system ensures accurate and precise pipetting results. By guiding pipetting steps, the unique plate tracker increases reliability in correctly filling microwell plates. The pipette's repetitive blow-out function facilitates dispensing of the very last sample droplets, even with viscous liquids.

  • Manufacturer: Biohit
    Model: Picus NxT Electronic

  • Volume Range (µL): 100 - 5000
    Channels: 1

Description: Hamilton 1705 Small RN, 22s Gauge, 50 µL, PT=3, Removable Needle Syringe, Each
Part Number: 80965

These syringes are the Gastight® version of the original 700 series syringes and are ideal for dispensing volumes from 1μL up to 500μL. Gastight® syringes are ideal for dispensing both liquids and gases and have a precision-machined PTFE plunger tip which creates a leak-free seal. With the tight fit, the tip essentially wipes the interior of the syringe barrel free of sample. This feature is particularly useful with heterogeneous samples as it reduces the chance that a deposit will occur and cause the plunger to freeze. Fluid path includes SST, borosilicate glass, and PTFE. Syringes are gas sterilizable. A variety of different terminations and needle point styles are available. Terminations include cemented needle, removable needle, luer tip, and PTFE luer lock. Syringe Terminations: Cemented needles for low volume syringes are cemented into the glass syringe barrel at a point corresponding to the zero graduation mark. With this termination, dead volume is limited to the internal volume of the needle. Not autoclavable. Needle gauge is determined by the syringe volume and are not user-selectable. Removable needles are a Hamilton-specific design. The design allows the needles to seat precisely at the zero graduation mark of the syringe. Users can select the needle gauge, length, and point style to optimize the syringe for custom applications. This termination allows for a removable needle without increasing the dead volume of the syringe and is ideal when there is a risk of the needle clogging. Autoclavable when disassembled. Repeated autoclaving will shorten syringe life. Luer tip needles are removable and fit over a ground glass hub which is tapered in the shape of a male luer. This termination will accept most hypodermic needles but was designed specifically for use with Hamilton Kel-F needles. This termination also increases the dead volume in the syringe, which may not be appropriate for some applications. Autoclavable to 115°C when disassembled. PTFE luer lock termination has a PTFE, male Luer taper with nickelplated brass locking hub for use with Kel-F needles, metal hub needles, and universal connectors. It is also used with Hamilton diluters/dispensers, OEM applications, and manual operations. The version with slots is used during the attachment to some instruments but does not effect the connection to needles. Not autoclavable (25mL and greater syringes). Needle Point Styles: Point style 2 is a sharp, beveled, curved, non-coring needle point recommended for septum penetration. Point style 3 is a blunt needle point for use with HPLC injection valves and for sample pipetting. Point style 5 is a conical needle with side port for penetration of septa, thin-gauged vinyls and plastics without coring.

  • Manufacturer: Hamilton
    Model: 1700

  • Volume Range (µL): 0 - 50
    Channels: SYRINGE

Description: Hamilton 1702 Small RN, 22s Gauge, 25 µL, PT=3, Removable Needle Syringe, Each
Part Number: 80265

These syringes are the Gastight® version of the original 700 series syringes and are ideal for dispensing volumes from 1μL up to 500μL. Gastight® syringes are ideal for dispensing both liquids and gases and have a precision-machined PTFE plunger tip which creates a leak-free seal. With the tight fit, the tip essentially wipes the interior of the syringe barrel free of sample. This feature is particularly useful with heterogeneous samples as it reduces the chance that a deposit will occur and cause the plunger to freeze. Fluid path includes SST, borosilicate glass, and PTFE. Syringes are gas sterilizable. A variety of different terminations and needle point styles are available. Terminations include cemented needle, removable needle, luer tip, and PTFE luer lock. Syringe Terminations: Cemented needles for low volume syringes are cemented into the glass syringe barrel at a point corresponding to the zero graduation mark. With this termination, dead volume is limited to the internal volume of the needle. Not autoclavable. Needle gauge is determined by the syringe volume and are not user-selectable. Removable needles are a Hamilton-specific design. The design allows the needles to seat precisely at the zero graduation mark of the syringe. Users can select the needle gauge, length, and point style to optimize the syringe for custom applications. This termination allows for a removable needle without increasing the dead volume of the syringe and is ideal when there is a risk of the needle clogging. Autoclavable when disassembled. Repeated autoclaving will shorten syringe life. Luer tip needles are removable and fit over a ground glass hub which is tapered in the shape of a male luer. This termination will accept most hypodermic needles but was designed specifically for use with Hamilton Kel-F needles. This termination also increases the dead volume in the syringe, which may not be appropriate for some applications. Autoclavable to 115°C when disassembled. PTFE luer lock termination has a PTFE, male Luer taper with nickelplated brass locking hub for use with Kel-F needles, metal hub needles, and universal connectors. It is also used with Hamilton diluters/dispensers, OEM applications, and manual operations. The version with slots is used during the attachment to some instruments but does not effect the connection to needles. Not autoclavable (25mL and greater syringes). Needle Point Styles: Point style 2 is a sharp, beveled, curved, non-coring needle point recommended for septum penetration. Point style 3 is a blunt needle point for use with HPLC injection valves and for sample pipetting. Point style 5 is a conical needle with side port for penetration of septa, thin-gauged vinyls and plastics without coring.

  • Manufacturer: Hamilton
    Model: 1700

  • Volume Range (µL): 0 - 25
    Channels: SYRINGE